Cable Installation (Interface Specific)
Full Speed USB
10. Configure the MS2420 scanner to match the host system’s USB parameters.
For Single Cable Applications:
The IBM OEM Full Speed USB English and Metric bar codes are located in the MS2xxx Stratos
Series Configuration Addendum (PN 00-02034x) under Scanner Configuration Bar Codes:
Single Cable Protocols for POS Compatibility, IBM OEM Full Speed USB.
For Dual Cable Applications:
The IBM OEM Full Speed USB Communication Defaults bar code is located in the MS2xxx
Stratos Series Configuration Addendum (PN 00-02034x) under Scanner Configuration Bar
Codes: Dual Cable Scanner Configuration Bar Codes, IBM OEM Full Speed USB
Communication Defaults and IBM OEM Full Speed USB Protocols.
For USB Serial Emulation Mode or Keyboard Emulation Mode Only
These features can only be used for Dual Cable Applications.
11. Configure the MS2420 scanner for USB Serial Emulation Mode or USB Keyboard Emulation Mode by
scanning the appropriate configuration bar codes in the USB section of the MetroSelect Configuration
Guide (PN 00-02407x) under Low Speed USB. Any low speed USB warnings may be disregarded when
utilizing these codes for a Full Speed USB scanner.
Note: These features can only be used for Dual Cable Applications. The IBM OEM Full Speed USB
Communication Defaults bar code listed in step 10 must be scanned before scanning one of
these bar codes or this feature will not work properly.