EAS Deactivation
SW1 and SW2 are the switch banks inside the Checkpoint device that set the deactivation range. The
following is a list of Checkpoint recommended switch bank settings.
Checkpoint Recommended Switch Bank Settings
SW1 SW2
Switch 1 and 6 ON Switch 1 and 6 ON
Switch 2, 3, 4, and 5 OFF Switch 2, 3, 4, and 5 OFF
All MS2420 models have a connector labeled EAS In on the bottom of the unit. An optional EAS cable
(PN 52-52511x or 52-52556x) available for purchase for connection between the Checkpoint device and the
scanner.
Figure 20. EAS Cable Connection (Bottom of MS2420)
The following figure shows the location of the EAS deactivation area for the MS2420 scanner. It is important to
pass the entire tag through this area to deactivate the security tag.
Figure 21. EAS Deactivation Area