IBM 32H3816 Network Card User Manual


 
¦ ¦ failed. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 41064 ¦ A 64 MB DRAM module in ¦ Call for service or exchange ¦
¦ ¦ adapter card slot 1 has ¦ the DRAM for a new one. ¦
¦ ¦ failed. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 41128 ¦ A 128 MB DRAM module in ¦ Call for service or exchange ¦
¦ ¦ adapter card slot 1 has ¦ the DRAM for a new one. ¦
¦ ¦ failed. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 42000 ¦ The SSA adapter has detected ¦ Call for service or: ¦
¦ ¦ that both DRAM modules are ¦ ¦
¦ ¦ failing. ¦ 1. Check whether both DRAM ¦
¦ ¦ ¦ modules are correctly ¦
¦ ¦ ¦ installed on the adapter ¦
¦ ¦ ¦ card. Make any ¦
¦ ¦ ¦ necessary corrections. ¦
¦ ¦ ¦ ¦
¦ ¦ ¦ 2. If this problem has ¦
¦ ¦ ¦ occurred immediately ¦
¦ ¦ ¦ after an upgrade to the ¦
¦ ¦ ¦ adapter card, check ¦
¦ ¦ ¦ whether the correct type ¦
¦ ¦ ¦ of DRAM modules have ¦
¦ ¦ ¦ been installed. Make ¦
¦ ¦ ¦ any necessary ¦
¦ ¦ ¦ corrections. ¦
¦ ¦ ¦ ¦
¦ ¦ ¦ 3. If the problem remains, ¦
¦ ¦ ¦ exchange the adapter ¦
¦ ¦ ¦ card for a new one. Do ¦
¦ ¦ ¦ not exchange any DRAM ¦
¦ ¦ ¦ modules yet. ¦
¦ ¦ ¦ ¦
¦ ¦ ¦ 4. Install the DRAM modules ¦
¦ ¦ ¦ from the original ¦
¦ ¦ ¦ adapter card onto the ¦
¦ ¦ ¦ new adapter card, then ¦
¦ ¦ ¦ install the new adapter ¦
¦ ¦ ¦ card. ¦
¦ ¦ ¦ ¦
¦ ¦ ¦ 5. If the problem remains, ¦
¦ ¦ ¦ exchange the DRAM ¦
¦ ¦ ¦ modules for new modules. ¦
¦ ¦ ¦ ¦
¦ ¦ ¦ 6. Install the new DRAM ¦
¦ ¦ ¦ modules onto the ¦
¦ ¦ ¦ original adapter card. ¦
¦ ¦ ¦ Reinstall the original ¦
¦ ¦ ¦ adapter card. ¦
+---------+-------------------------------+------------------------------¦
¦ 42500 ¦ The SSA adapter has detected ¦ Call for service ¦
¦ ¦ a failure in the write cache. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 43PAA ¦ An SSA device is preventing ¦ Call for service ¦
¦ ¦ the completion of the loop ¦ ¦
¦ ¦ configuration. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 45PAA ¦ The SSA adapter has detected ¦ Call for service ¦
¦ ¦ an open SSA loop. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 46000 ¦ A RAID array is the Offline ¦ Call for service ¦
¦ ¦ state because more than one ¦ ¦
¦ ¦ disk drive is not available. ¦ ¦
¦ ¦ At least one member disk ¦ ¦
¦ ¦ drive of the array is ¦ ¦
¦ ¦ present, but more than one ¦ ¦
¦ ¦ member disk drive is missing. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 47000 ¦ An attempt has been made to ¦ Call for service ¦
¦ ¦ store in the SSA adapter the ¦ ¦
¦ ¦ details of more than 32 RAID ¦ ¦
¦ ¦ arrays. ¦ ¦
+---------+-------------------------------+------------------------------¦
SSA RAID Adapter Installation and User's Guide.
Appendix B. SSA RAID Adapter Service Request Numbers
_ Copyright IBM Corp. 1996
B.0 - 2