¦ 47500 ¦ Part of the RAID array data ¦ Call for service ¦
¦ ¦ might have been lost. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 48000 ¦ The SSA adapter has detected ¦ Go to "SSA Loop ¦
¦ ¦ a loop configuration that is ¦ Configurations that Are Not ¦
¦ ¦ not valid. ¦ Valid" in topic B.1 or call ¦
¦ ¦ ¦ for service ¦
+---------+-------------------------------+------------------------------¦
¦ 49000 ¦ A RAID array is in the ¦ Call for service ¦
¦ ¦ Degraded state because a disk ¦ ¦
¦ ¦ drive is not available to the ¦ ¦
¦ ¦ array, and a write command ¦ ¦
¦ ¦ has been sent to that array. ¦ ¦
¦ ¦ ¦ ¦
¦ ¦ A disk drive might not be ¦ ¦
¦ ¦ available for one of the ¦ ¦
¦ ¦ following reasons: ¦ ¦
¦ ¦ ¦ ¦
¦ ¦ The disk drive has ¦ ¦
¦ ¦ failed. ¦ ¦
¦ ¦ The disk drive has been ¦ ¦
¦ ¦ removed from the ¦ ¦
¦ ¦ subsystem. ¦ ¦
¦ ¦ An SSA link has failed. ¦ ¦
¦ ¦ A power failure has ¦ ¦
¦ ¦ occurred. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 49100 ¦ A RAID array is in the ¦ Call for service ¦
¦ ¦ Exposed state because a disk ¦ ¦
¦ ¦ drive is not available to the ¦ ¦
¦ ¦ array. ¦ ¦
¦ ¦ ¦ ¦
¦ ¦ A disk drive can become not ¦ ¦
¦ ¦ available for several ¦ ¦
¦ ¦ reasons: ¦ ¦
¦ ¦ ¦ ¦
¦ ¦ The disk drive has ¦ ¦
¦ ¦ failed. ¦ ¦
¦ ¦ The disk drive has been ¦ ¦
¦ ¦ removed from the ¦ ¦
¦ ¦ subsystem. ¦ ¦
¦ ¦ An SSA link has failed. ¦ ¦
¦ ¦ A power failure has ¦ ¦
¦ ¦ occurred. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 49500 ¦ No hot-spare disk drives are ¦ Call for service ¦
¦ ¦ available for a RAID array ¦ ¦
¦ ¦ that is configured for ¦ ¦
¦ ¦ hot-spare disk drives. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 49700 ¦ The parity for the RAID array ¦ Call for service ¦
¦ ¦ is not complete. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 50000 ¦ The SSA adapter failed to ¦ Exchange the adapter card ¦
¦ ¦ respond to the device driver. ¦ for a new one or call for ¦
¦ ¦ ¦ service ¦
+---------+-------------------------------+------------------------------¦
¦ 50001 ¦ A data parity error has ¦ Exchange the adapter card ¦
¦ ¦ occurred. ¦ for a new one or call for ¦
¦ ¦ ¦ service ¦
+---------+-------------------------------+------------------------------¦
¦ 50002 ¦ An SSA adapter DMA error has ¦ Exchange the adapter card ¦
¦ ¦ occurred. ¦ for a new one or call for ¦
¦ ¦ ¦ service ¦
+---------+-------------------------------+------------------------------¦
¦ 50004 ¦ Channel check. ¦ Exchange the adapter card ¦
¦ ¦ ¦ for a new one or call for ¦
¦ ¦ ¦ service ¦
+---------+-------------------------------+------------------------------¦
¦ 50005 ¦ A software error has ¦ Call for service ¦
¦ ¦ occurred. ¦ ¦
+---------+-------------------------------+------------------------------¦
¦ 50006 ¦ A channel check has occurred. ¦ Exchange the adapter card ¦
¦ ¦ ¦ for a new one or call for ¦
SSA RAID Adapter Installation and User's Guide.
Appendix B. SSA RAID Adapter Service Request Numbers
_ Copyright IBM Corp. 1996
B.0 - 3