50
Error Condition
0: No error
1: Lamp not lit after 5
attempts
3: Lamp went out
unexpectedly
4: Fan failure
5: Overtemperature
6: Low voltage
?: Query
ERR R 0 6 0 1
Factory Reset
1: Reset
RST W 1
Fan Position
0: Normal
1: Vertical
2: Down
FNP RW 0 2 0 1
Firmware Version FWV R string
Focus Far
0: Fine Step
1: Large Step
MFF W 0 1 1 1
Focus Near
0: Fine Step
1: Large Step
MFN W 0 1 1 1
Gamma
0: Film
1: Graphics
2: Video
3: Linear
GTB RW 0 3 Source
Specific
1
Gateway Address
GT1: 1st Octet
GT2: 2nd Octet
GT3: 3rd Octet
GT4: 4th Octet
GTn RW 0 255 0 1
Green Gain GCG RW 0 200 100 1
Green Offset GCO RW 0 200 100 1
High Altitude Mode HAL RW 0 1 0 1
Horz. Keystone DHK RW -350 350 0 1
Horz. Refresh Rate QHR R string
Horz. Total HZT RW 0 200 100 1
Horz. Position HPS RW 0 200 100 1
Horz. Phase HPH RW 0 200 100 1
Input Lock
0: Auto
1: 48Hz
2: 50Hz
3: 60Hz
ILC RW 0 3 0 1
IP Address
IP1: 1st Octet
IP2: 2nd Octet
IP3: 3rd Octet
IP4: 4th Octet
IPn RW 0 255 0 1
Lamp 1 Hours
?: Query
LMP R 0 n/a string 1
Lamp 1 Reset
1: Reset
LMR W 1
Lamp 1 Status
0: Off
1: On
DLS R 0 1 1 1
Lamp 2 Hours
?: Query
LDH R 0 n/a string 1
Lamp 2 Reset
1: Reset
LDR W 1