JVC HD-61G587 Computer Monitor User Manual


 
63
Lamp Replacement
How to Replace the Lamp
Please read these instructions fully before attempting to replace the lamp. If you feel
unsure about replacing the lamp yourself, call a service technician. Please observe all
safety warnings.
1) Turn off the monitor.
Press the POWER button on the remote control or monitor front panel. Wait until the picture
has closed and the LAMP LED on the front panel has stopped blinking indicating the lamp cool
down is complete.
Warning: The cool-down process cools the lamp from its operating temperature. This
does not mean that the lamp will now be cool enough to handle safely. We strongly
recommend you wait at least one hour before proceeding.
2) Unplug the monitor.
Disconnect the power cord from the AC outlet. Make sure that the LAMP LED light has stopped
blinking before you unplug the set. Never attempt to replace the lamp with the monitor plugged
in.
3) Remove the lamp cover.
The lamp is located behind the lamp cover below the left side of the
monitor. To access the lamp you will need to remove the lamp cover. First,
remove the screw located on the lamp cover using a Philips head type
screwdriver (cross-head type). Once the screw has been removed, gently
pull the knob towards you and the panel will come away from the monitor.
Set it aside.
WARNING: DO NOT attempt to remove the assembly until the lamp has fully cooled. If you
feel any heat near the lamp, STOP and wait until the lamp has FULLY COOLED.
NEVER attempt to remove the lamp with the monitor plugged into an outlet.
DO NOT DROP the used lamp. The inside of the lamp is under pressure. Dropping or other
hard shock could cause the lamp to shatter.
ALWAYS recycle the used lamp. Because the lamp contains a small amount of mercury, it
cannot be thrown away with regular trash. Follow the recycling instructions included with the
Lamp Replacement Kit.
4) Remove the lamp unit.
Using a Philips head type screwdriver (cross-head type), loosen the two screws fastening the
lamp unit. When the screws have been loosened, remove the lamp by raising the handle and
gently sliding the unit straight towards you. Place it carefully in the recycling packaging.
LCT2065-001B-A ENG.indd 63LCT2065-001B-A ENG.indd 63 12/18/06 10:11:13 AM12/18/06 10:11:13 AM