Kodak 3000DSV-E Scanner User Manual


 
5-2 A-61371 September 2004
Carrier Glass (option)
NOTE: Before cleaning the carrier glass, remove the projection lens
from the scanner. Refere to Chapter 3, “Installing the projection
lens” for procedures.
With a damp cloth, clean and remove any dust or debris from the
surface of the carrier glass.
To open the carrier glass:
Pull the handle of the microfiche holder. With a damp cloth, clean and
remove dust and debris by wiping the inner surfaces of the carrier
glass.
Replacing the
projection lamp
Use the following procedure to replace the projection lamp whenever a
reduction in brightness on the screen is detected or whenever the lamp
burns out. Make sure that the replacement lamp is specified for use
with this scanner.
If the projection lamp burns out during a print operation, an L2 code
appears and the print job will stop (a blank piece of paper may be
output depending upon the stage of the job).
Once the system detects that the projection lamp has burnt out, the
scan job will be cancelled. If the system is operating in the Cycle Print
mode, the scanner operation will stop.
To replace the projection lamp:
1. Turn the power switch off and unplug the power cord from the wall
socket-outlet. Grasp the power cord plug only when unplugging the
power cord.
WARNING:Never touch the lamp with bare hands just after
operation or immediately after turning it off. Wait
at least 10 minutes after shutting the power off to
allow the lamp to cool down as it becomes very
hot during use.