Kodak 3000DSV-E Scanner User Manual


 
A-61371 September 2004 B-1
Appendix B User and System Settings
This system offers two types of settings:
User settings that are set up by the operator from the control panel.
System settings that are set up and can be changed by the Kodak
Service Representative.
Following is a list of factory settings:
NOTE: When any of these functions has been changed and you want to
store the new setting in the system’s memory, press the
Memory Input key.
User Settings Initial Setting Remark
Exposure mode Auto
Print image density Center
Paper size Letter (A4)
Print position Center
Film type Auto
Auto Skew Correction ON
Auto Masking ON
Manual Masking - Enabled only when the Manual
Masking Kit (option) is mounted.
Centering/Fit OFF
System Setting Selection Default Description
Auto Reset Enabled
Disabled
Enabled Setting changes made to the control panel that are not
used within 60 seconds of being input are
automatically cancelled and the system reverts back to
the original settings.
Auto power save
(PR mode only)
Disabled
30 min.
60 min.
Disabled Turns the printer’s fuser off if the system is left idle for
a specific period of time.
NOTE:230V units operate on a 30-minute Auto Power
Save setting.
Auto Projection Lamp OFF Disabled
30 min.
60 min.
Disabled Turns the projection lamp off if the system is left idle for
a specified period of time.
Fine mode contrast select Contrast
Emphasis
Outline
Emphasis
Contrast
Emphasis
Applies the following functions as required:
Contrast Emphasis: applied when film contains text
that is poorly contrasted against its background
making it difficult to read.
Outline Emphasis: applied when film contains blurred
black-and-white images.
Auto Skew Correction
Retain
Retained
Not Retained
Not
Retained
Determines whether or not to retain the original
(uncorrected) skew of a screen image after the print
has been made.