34 VS-88DTP - Default Communication Parameters
9 Default Communication Parameters
EDID
EDID data is passed between Output 1 and Input 1
RS-232
Protocol 2000 Protocol 3000 (Default)
Baud Rate: 9600 Baud Rate: 115,200
Data Bits: 8 Data Bits: 8
Stop Bits: 1 Stop Bits: 1
Parity: None Parity: None
Command Format: HEX Command Format: ASCII
Example (Output 1 to
Input 1):
0x01, 0x81, 0x81,
0x81
Example (Output 1 to
Input 1):
#AV 1>1<CR>
Switching Protocol
P2000 -> P3000 P3000 -> P2000
Command: 0x38, 0x80, 0x83,
0x81
Command: #P2000<CR>
Ethernet
Default Settings Reset Settings
IP Address: 192.168.1.39 Power cycle the unit while holding in the
Factory Reset button, located on the rear
panel of the unit.
TCP Port #: 5000
UDP Port #: 50000
The Windows®-based Kramer control software (available for
download the latest software from our Web site at
http://www.kramerelectronics.com)
operates with protocol 2000.
If the VS-88DTP is set to protocol 3000, it is automatically switched
to protocol 2000
i