Kramer Electronics VS-88DTP Switch User Manual


 
48 VS-88DTP - Kramer Protocol
Instruction Codes for Protocol 2000
Instruction Definition for Specific Instruction Notes
# Description Input Output
0
RESET VIDEO
0
0
1
1 SWITCH VIDEO Set equal to video input that is
to be switched
(0 = disconnect)
Set equal to video output which
is to be switched
(0 = to all the outputs)
2, 15
3
STORE VIDEO STATUS
Set as SETUP #
0 - to store
1 - to delete
2, 3, 15
4 RECALL VIDEO STATUS Set as SETUP # 0 2, 3, 15
5 REQUEST STATUS OF A
VIDEO OUTPUT
Set as SETUP # Equal to output number whose
status is required
4, 3
15
REQUEST WHETHER SETUP
IS DEFINED / VALID INPUT
IS DETECTED
SETUP #
or
Input #
0 - for checking if setup is
defined
1 - for checking if input is valid
8
16 ERROR / BUSY For invalid / valid input (i.e.
OUTPUT byte = 4 or OUTPUT
byte = 5), this byte is set as the
input #
0 - error
1 - invalid instruction
2 - out of range
3 - machine busy
4 - invalid input
5 - valid input
6 - RX buffer overflow
9, 25
30 LOCK FRONT PANEL 0 - Panel unlocked
1 - Panel locked
0 2
31
REQUEST WHETHER PANEL
IS LOCKED
0
0
16
56 CHANGE TO ASCII 0 Kramer protocol 3000 19
61 IDENTIFY MACHINE 1 - video machine name
2 - audio machine name
3 - video software version
4 - audio software version
5 - RS422 controller name
6 - RS422 controller version
7 - remote control name
8 - remote software version
9 - Protocol 2000 revision
0 - Request first 4 digits
1 - Request first suffix
2 - Request second suffix
3 - Request third suffix
10 - Request first prefix
11 - Request second prefix
12 - Request third prefix
13
62
DEFINE MACHINE
1 - number of inputs
2 - number of outputs
3 - number of setups
1 - for video
2 - for audio
14
NOTES on the above table:
NOTE 1 - When the master switcher is reset, (e.g. when it is turned on), the reset code is sent to the PC. If this code is
sent to the switchers, it will reset according to the present power-down settings.
NOTE 2 - These are bi-directional definitions. That is, if the switcher receives the code, it will perform the instruction; and
if the instruction is performed (due to a keystroke operation on the front panel), then these codes are sent. For example,
if the HEX code
01 85 88 83
was sent from the PC, then the switcher (machine 3) will switch input 5 to output 8. If the user switched input 1 to output
7 via the front panel keypad, then the switcher will send HEX codes:
41 81 87 83
to the PC.
When the PC sends one of the commands in this group to the switcher, then, if the instruction is valid, the switcher
replies by sending to the PC the same four bytes that it was sent (except for the first byte, where the DESTINATION bit
is set high).
NOTE 3 - SETUP # 0 is the present setting. SETUP # 1 and higher are the settings saved in the switcher's memory, (i.e.
those used for Store and Recall).
NOTE 4 - The reply to a "REQUEST" instruction is as follows: the same instruction and INPUT codes as were sent are
returned, and the OUTPUT is assigned the value of the requested parameter. The replies to instructions 10 and 11 are
as per the definitions in instructions 7 and 8 respectively. For example, if the present status of machine number 5 is
breakaway setting, then the reply to the HEX code
0B 80 80 85
would be HEX codes
4B 80 81 85