Kramer Electronics VS-88DTP Switch User Manual


 
VS-88DTP - Hex Codes for Serial Communication (Protocol 2000) 39
13 Hex Codes for Serial Communication
(Protocol 2000)
The Hex codes listed in this section are used to set video channels for a single
machine (set as Machine 1) connected via either RS-232 or Ethernet. Similar hex
codes are used when the VS-88DTP is connected via RS-485 and the machine is
set to number 2.
The following table lists the Hex codes that switch video channels:
Video Channel Switching Codes
OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8
IN 1
01 81 81 81 01 81 82 81 01 81 83 81 01 81 84 81 01 81 85 81 01 81 86 81 01 81 87 81 01 81 88 81
IN 2
01 82 81 81 01 82 82 81 01 82 83 81 01 82 84 81 01 82 85 81 01 82 86 81 01 82 87 81 01 82 88 81
IN 3
01 83 81 81 01 83 82 81 01 83 83 81 01 83 84 81 01 83 85 81 01 83 86 81 01 83 87 81 01 83 88 81
IN 4
01 84 81 81 01 84 82 81 01 84 83 81 01 84 81 84 01 84 85 81 01 84 86 81 01 84 87 81 01 84 88 81
IN 5
01 85 81 81 01 85 82 81 01 85 83 81 01 85 84 81 01 85 85 81 01 85 86 81 01 85 87 81 01 85 88 81
IN 6
01 86 81 81 01 86 82 81 01 86 83 81 01 86 84 81 01 86 85 81 01 86 86 81 01 86 87 81 01 86 88 81
IN 7
01 87 81 81 01 87 82 81 01 87 83 81 01 87 84 81 01 87 85 81 01 87 86 81 01 87 87 81 01 87 88 81
IN 8
01 88 81 81 01 88 82 81 01 88 83 81 01 88 84 81 01 88 85 81 01 88 86 81 01 88 87 81 01 88 88 81