Lantronix 900-581 Computer Hardware User Manual


 
5: Commands and Levels
key 4 (config-profile-security-wep-key:test1:4) level commands
apply wlan
Try out WLAN settings without saving them to Flash.
If the settings do not work, when you reboot the device,
it will still have the original settings.
clrscrn
Clears the screen.
exit
Exits to the next higher level.
key <hexadecimal>
Sets key.
Each byte is represented by two adjacent hex digits.
Bytes may run together or be separated by optional punctuation:
123ABC "12 3A BC" 12,3A,BC 12.3a.bc 12:3a:bc
Note that quotes must enclose the value if it contains spaces.
key text <text>
Sets key.
Each byte is represented by a single character.
Note that quotes must enclose the value if it contains spaces.
no key
Removes key.
show
Shows the current configuration.
show history
Displays the last 20 commands entered during the current CLI
session.
write
Stores the current configuration in permanent memory.
key 4 (config-profile-security-wep-key:default_adhoc_profile:4) level commands
apply wlan
Try out WLAN settings without saving them to Flash.
If the settings do not work, when you reboot the device,
it will still have the original settings.
clrscrn
Clears the screen.
exit
Exits to the next higher level.
key <hexadecimal>
Sets key.
Each byte is represented by two adjacent hex digits.
Bytes may run together or be separated by optional punctuation:
123ABC "12 3A BC" 12,3A,BC 12.3a.bc 12:3a:bc
Note that quotes must enclose the value if it contains spaces.
key text <text>
Sets key.
Each byte is represented by a single character.
Note that quotes must enclose the value if it contains spaces.
no key
Removes key.
show
Shows the current configuration.
show history
Displays the last 20 commands entered during the current CLI
session.
write
Stores the current configuration in permanent memory.
line 1 (line:1) level commands
auto show statistics
Continuously displays line statistics.
baud rate <bits per second>
Sets the line speed.
<bits per second> = the speed.
Standard speeds include 1200, 2400, 4800, 9600, 19200, and so
on.
clear line counters
Sets the serial counters to zero.
clrscrn
Clears the screen.
command mode always
Sets the current line to always be in command mode.
command mode echo serial string disable
Disables user-defined serial boot string to be echoed in the CLI.
command mode echo serial string enable
Enables user-defined serial boot string to be echoed in the CLI.
command mode serial string
Enables user to enter a custom string at boot time to enter com-
PremierWave EN Command Reference 183