Leica RX1200 Calculator User Manual


 
Operation RX1200 65
4.2 Batteries
4.2.1 Operating Principles
)
This chapter is valid for RX1220, RX1250 and GHT56.
)
Primary use/charging
The battery must be charged prior to using it for the first time because it is deliv-
ered with an energy content as low as possible.
For new batteries or batteries that have been stored for a long time (> three
months), it is effectual to make only one charge/discharge cycle.
For Li-Ion batteries, a single discharging and charging cycle is sufficient. We
recommend carrying out the process when the battery capacity indicated on the
charger or on a Leica Geosystems product deviates significantly from the actual
battery capacity available.
The permissible temperature range for charging is between 0°C to +40°C/ +32°F
to +104°F. For optimal charging we recommend charging the batteries at a low
ambient temperature of +10°C to +20°C/+50°F to +68°F if possible.
It is normal for the battery to become warm during charging. Using the chargers
recommended by Leica Geosystems, it is not possible to charge the battery if
the temperature is too high.