Lexmark X502N Computer Monitor User Manual


 
Replace the fuser if the defects occur every:
95 mm (3.74 in.)
128 mm (5.04 in.)
Color misregistration
ABCDEABCDE
ABCDE
ABCDE
Color has shifted outside of the appropriate area or has been superimposed over another color area.
Remove and reinstall the toner cartridges.
Remove and reinstall the photodeveloper cartridge.
Light colored line, white line, or incorrectly colored line
These are possible solutions. Try one or more of the following:
Clean the dust-proof glass
The dust-proof glass may be dirty.
Is a toner cartridge defective?
Replace the toner cartridge causing the line.
Is a photodeveloper cartridge defective?
Replace the photodeveloper cartridge.
Smeared vertical print