8 AC power system description
Pedestal Power Distribution Unit (PDU)
The Pedestal PDU provides the following:
-
The Field Wiring Terminal Block provides a connection point for the
external wiring that is brought into the Pedestal.
-
The EM1 Filter provides filtering of the wires connecting back to the
Utility in order to meet FCC and DOC requirements.
-
The Main Circuit Breaker provides both a single protection device for
overload currents and a single trip device to shut down the column in the
event of a thermal overload.
-
The Internal Terminal Block provides individual power hand-off points so
that each Module is independently powered from the Pedestal in order to
minimize wire size.
.
-
The Power/Signal Harness provides the Power and Signal interconnections
in the Pedestal for the Blower Unit and System Monitor.
. .
-
The System Monitor Power Supply (a small +5V power supply) provides
power to the System Monitor, even when the main circuit breaker has
tripped.
-
The Output Power Harness provides the independent power connections
from the Pedestal to the Module above it.
-
Module to Module Harness
The Module to Module Harness provides the following:
-
The Module Feed provides the independent power feed(s) to the Module
above itself.
-
The Module PDU Feed provides the power feed to the Module PDU.
Module Power Distribution Unit (MPDU)
The Module PDU provides the following functions:
-
The Circuit Breaker provides a Module level of current protection so that a
fault on one Module will be disconnected while the other Modules remain
functional.
e-
,-..--
_.,,.
-,-.
-3
-
The MPDU to Backplane Harness feed provides the power feed to the
backplane harness which in turn provides power to the AC Power
Supplies through the backplane power connector.