MRV Communications TS5000/ETH/V* Mouse User Manual


 
MRV Communications, Inc. – Installation Manual
56
TS5000/ETH
Part Number
TS5000/ETH/V*
Model
TS5000/ETH
Standard P.N
TS5000/ETH/VS
Application /
Data Protocol
Ethernet (10 Mbps)
Rate 10Mbps
Range
(1)
@ 3dB/km 6700 m
@ 5dB/km 5000 m
@ 10dB/km 3200 m
@ 17dB/km 2170 m
@ 30dB/km 1400 m
Minimum Range 400 m
Bit Error Rate Less than 1E-9 (unfaded)
Performance
MTBF 10 years
Light source 3 x Lasers
Wavelength 830-860 nm
Total Output power 85 mW
Transmitter
Beam divergence 2 mrad
Detector APD
Field of view 2 mrad
Receiver
Sensitivity -55 dBm
Type Copper 10BaseT
Connectors RJ45
Interface
Cable STP
Power Supply
Factory set: 100-240 VAC @ 50/60 Hz or 35-60 VDC (V3 Version)
(30 W)
Operating Temp.
-30 °C to +50 °C
Storage Temp.
-50 °C to +70 °C
Humidity 95% non-condensing
Housing Weatherproof – IP 66
Environmental
Information
Eye safety Class 1M
Dimensions [mm] 790 X 390 X 556 (AD-5000: 250x353x432)
Unit 14 kg Weight
Accessories 21.5kg
Mechanical
Design
Modularity Modular Power supply
Indicators Airlink: Flag, Data. 10Base-T: Flag, Data.
Receive Signal Strength (Digital Display),
Lasers status (3 LEDs)
Selectors IP address setting
Dry Contact
One pair of Pins of the main RJ45 connector can be used for
dry contact purposes, for Airlink flag alarm
Diagnostics
Indicators
and
Selectors
Management SNMP Protocol – Built-in