NEC 320Lb Server User Manual


 
5-18 Problem Solving
STATUS LED
Error Message
Color State
Suspected module Description Procedure
Cor1 +3.3vAlm 02
Amber Lit PCI module #2
Fatal 3.3-V power voltage alarm
(lower limit)
Cor1 +3.3vAlm 07
Amber Blink PCI module #2 3.3-V power voltage alarm (upper
limit)
Cor1 +3.3vAlm 09
Amber Lit PCI module #2 Fatal 3.3-V power voltage alarm
(upper limit)
Cor1 +3.3vsAlm
00
Amber Blink PCI module #2 3.3-V power voltage alarm (lower
limit)
Cor1 +3.3vsAlm
02
Amber Lit PCI module #2 Fatal 3.3-V power voltage alarm
(lower limit)
Cor1 +3.3vsAlm
07
Amber Blink PCI module #2
3.3-V power voltage alarm (upper
limit)
Cor1 +3.3vsAlm
09
Amber Lit PCI module #2 Fatal 3.3-V power voltage alarm
(upper limit)
Cor1 +5.0vAlm 00
Amber Blink PCI module #2 5-V power voltage alarm (lower
limit)
Cor1 +5.0vAlm 02
Amber Lit PCI module #2 Fatal 5-V power voltage alarm
(lower limit)
Cor1 +5.0vAlm 07
Amber Blink PCI module #2 5-V power voltage alarm (upper
limit)
Cor1 +5.0vAlm 09
Amber Lit PCI module #2 Fatal 5-V power voltage alarm
(upper limit)
Cor1 +5.0vsAlm
00
Amber Blink PCI module #2
5-V power voltage alarm (lower
limit)
Cor1 +5.0vsAlm
02
Amber Lit PCI module #2 Fatal 5-V power voltage alarm
(lower limit)
Cor1 +5.0vsAlm
07
Amber Blink PCI module #2 5-V power voltage alarm (upper
limit)
Cor1 +5.0vsAlm
09
Amber Lit PCI module #2 Fatal 5-V power voltage alarm
(upper limit)
Cor1 -12vAlm 00
Amber Blink PCI module #2 -12-V power voltage alarm (lower
limit)
Cor1 -12vAlm 02
Amber Lit PCI module #2 Fatal -12-V power voltage alarm
(lower limit)
Cor1 -12vAlm 07
Amber Blink PCI module #2 -12-V power voltage alarm (upper
limit)
Cor1 -12vAlm 09
Amber Lit PCI module #2 Fatal -12-V power voltage alarm
(upper limit)
Cor1 Bus PERR 01
Green Blink PCI module #2 PCI bus parity error
Cor1 Bus SERR 01
Green Blink PCI module #2 Fatal PCI bus error
Cor1 CLK Alm 00
Amber Blink CLOCK board Clock alarm (lower limit)
Cor1 CLK Alm 02
Amber Lit CLOCK board Fatal Clock alarm (lower limit)
Cor1 CLK Alm 07
Amber Blink CLOCK board Clock alarm (upper limit)
Cor1 CLK Alm 09
Amber Lit CLOCK board Fatal Clock alarm (upper limit)
Contact your sales agent.
Cor1 FAN Alm 01
Amber Blink PCI module #2 Cooling fan1 alarm
Cor1 FAN Alm 02
Amber Blink PCI module #2 Cooling fan2 alarm
Cor1 FAN Alm 03
Amber Blink PCI module #2 Cooling fan3 alarm
Cor1 FAN Alm 04
Amber Blink PCI module #2 Cooling fan4 alarm
Cor1 FAN Alm 05
Amber Blink PCI module #2 Cooling fan5 alarm
Check to see if dust is
accumulated on the internal
fans. Check also if the fan
cables are connected securely.
If not solved by the above,
contact your sales agent.