NETGEAR 700 Series Switch User Manual


 
700 Series Managed Switch User’s Guide for Software v2.1
6-12 Command Line Interface
SM-10004-02
<VLAN index #> = The VLAN ID. Adding the VLAN ID to the show vlan command displays
the port that belongs to that particular VLAN. For example, show vlan 1 displays the ports that
belong to VLAN 1.
An example of the display output is shown below:.
Untagged port members: 4,5,7,11-15,19-23
Tagged port members: none
COS-PVID
The show vlan cos-pvid displays the PVIDs and the CoS settings of each port.
Syntax
FSM726# show vlan cos-pvid
An example of the display output is shown below:
Port PVID Priority
------------------------
1:1 1 Normal
1:2 1 Normal
1:3 1 Normal
1:4 1 Normal
1:5 1 Normal
Configure
Entering the command configure at the root prompt takes you into configuration mode. When
you’re in configuration mode, the prompt changes to
FSM726(config)#
It is in this mode where the vast majority of configuration is performed. To exit the configuration
mode and return to root prompt, use the exit command.
DiffServ
DiffServ divides traffic into one of 64 classes using the packet’s DSCP value. This allows for
greater differentiation of traffic priority than port-based traffic prioritization.
Syntax