Data Network Terminal Single-port and Multiport Operating Instructions
42 (128) © Nokia Corporation DN01145897
Nokia Proprietary and Confidential Issue2-0en
Note
Note
Port settings (Q1: 6,4, port#,3)
Different adapters include different configurable parameters. Check that port
settings are compatible with the equipment they are connected to.
There are some adapter settings that are done by changing the jumper settings on
the actual adapter. For more information, refer to document DTE Interface Units
for Nokia Data Network Terminals Operating Instructions.
Port alarms (Q1: 6,4, port#,5)
Check that the Q1 alarm visibility is set correctly, that is, enabled or disabled. If
Q1 alarms are disabled, port alarms are not visible in the NMS system.
Also, the BER alarm limit and the alarm severity need to be checked.
6.6 Time slot settings (Q1: 6,5)
DNT2Mi can map a certain amount of time slots from the line connection directly
to a port. Check and configure the time slot allocations, if necessary.
Pay close attention to the mapping of time slot 0. For example, time slot 0 cannot
be mapped with G.704 adapters.
6.7 Protection settings
Password (Q1: 10,1 and 10,4)
DNT2Mi settings can be protected with a password.
Front panel key rights (Q1: 10,5)
The front panel keys can be used to configure the equipment and to launch tests
(Test activation). Both functions can be either enabled or disabled.