Nokia DNT2Mi sp/mp Network Router User Manual


 
Data Network Terminal Single-port and Multiport Operating Instructions
98 (128) © Nokia Corporation DN01145897
Nokia Proprietary and Confidential Issue2-0en
Q1 address (6,1,2)
The Q1 address must be selected before DNT2Mi can be accessed using
management.
The address can range from 0000 to 4095. The last address (4095) is a universal
address that cannot be selected by the Q1 manager.
Q1 management path (6,1,3)
A Q1 management source is selected from this menu. The source can either be:
Q1 via line, EOC
Local management interface
Q1 via Port1 (only with G.704 adapter).
9.3.3 Timing source (6,2)
This menu allows you to select a source for timing. The timing alternatives are:
Internal
Line
Port1
Transparent.
Figure 73 illustrates the principle of each alternative.
The timing of circuit 103 can be set either by the clock from DTE (113) or by the
clock of the equipment (114). See Figures 78 and 79 in Section 9.3.5.