Nortel Networks 53r 5300 00 Network Card User Manual


 
Configuring the Primary (EMS1) and Secondary (EMS2) clock source servers 49
Select Y to enable system audit. Enabling the system audit might
impact system performance.
The system displays a validation summary of the current
configuration settings.
7
Do one of the following:
Type Y to confirm the configuration settings and continue with
the Linux installation process.
OR
Type N to go back through the individual configuration steps and
make changes.
After you confirm the settings, the installation process continues.
--End--
Configuring the Primary (EMS1) and Secondary (EMS2) clock
source servers
Use this procedure to configure the primary and secondary clock source
servers.
Prerequisites
You selected option 1 or 2 at the Clock Source function prompt.
Procedure Steps
Step Action
1
Do one of the following:
Select E to use an external clock source (recommended).
OR
Select I to use an internal clock source (not recommended). If
this option is selected, proceed to step 4.
2 Enter the number of external clock sources to reference (1-10).
3 Enter the IP addresses of the external clock source servers.
The system displays the following prompt:
Enter the MACHINE Logical IP Address of the
<Primary/Secondary> Clock Source Server
4 If you are configuring the Primary (EMS1) server, enter the
machine logical address of the Secondary (EMS2) server.
OR
Application Server 5300
Nortel AS 5300 Installation
NN42040-300 01.04
4 November 2008