Nortel Networks 53r 5300 00 Network Card User Manual


 
92 Maintenance Releases
The load name listed for each instance is the patched load.
--End--
Upgrading the AudioCodes gateway
Use this procedure to apply the Maintenance Release upgrades to
the AudioCodes gateway. The only supported method for the AS5300
AudioCodes deployment of loads and upgrades must be done by the
SunFire V-215 EMS servers.
Attention: The AudioCodes gateway does not have the capability to
switch its activity to another instance. Upgrading an AudioCodes gateway
causes service loss and all calls connected through that gateway are
dropped.
Procedure Steps
Step Action
1 From the EMS MG Tree pane, select the AudioCodes gateway
to be upgraded. The Info pane and the Status pane now display
the AudioCodes gateway.
2 From the Info pane, selectSoftware Upgrade. The Files
Manager screen is displayed.
3 Select the appropriate software (CMP) to be downloaded and
click OK in the Files Manager screen. A Question screen is
displayed.
4
From the Question screen, selectSystem Reset Upgrade and
click Yes.
The selected software (CMP) is downloaded to the AudioCodes
gateway, and the AudioCodes gateway is reset.
--End--
Applying the Linux Maintenance Release
Use this procedure to apply the Maintenance Release for the Linux
operating system.
Prerequisites
Linux is installed on the system.
Application Server 5300
Nortel AS 5300 Installation
NN42040-300 01.04
4 November 2008
Copyright © 2007-2008 Nortel Networks
.