Refer to the following
page and item on
Page / Category -
Section
□
Have precautions been checked in the case of switching with both high
and low loads by the same contact?
p9/7-1
□
Doesn't heat dissipation occur under low temperature? p9/7-2
□
Has transient state of contact resistance been considered? p9/8-1
□
Are contact voltage and current 6V 1A or higher? p9/8-2
Operating sound
□
Are there any problems regarding operating sound of relay? p9/9-1、p9/9-2
Mechanical
noise
□
Are there any problems regarding abnormal weak noise of relay? p9/10-1、p9/10-2
□
Is temperature, humidity, atomosphere pressure within the range of use? p10/12-1
□
Have precautions been checked in the case of switching under high
humidity?
p10/12-1
□
Is the ambient environment free from particles, dusts, sulfidizing gas,
organic gas?
p10/12-2
□
Is the ambient environment free from silicon? p10/12-3
□
Is the ambient environment free from high-field magnetic instruments
such as speaker?
p10/12-4
□
Are the ambient vibration and shock below the relay's vibration and
impact characteristics? Also, is there no resonance after the relay is
p10/12-5、p10/12-6
□
Isn't there a risk of freezing and dewing of relay? p9/7-2、p10/12-7、p
11/12-9
□
Isn't there a risk of water or oil adhesion? p11/12-8
Mounting
□
Doesn't vibration or shock cause poor connection between a relay and a
connector?
p11/13-1
□
Have precautions been checked for operating of flux applying and
automatic soldering?
p13/15-1、p15/15-2
□
Have precautions been checked for cleaning operation of print board? p13/15-1、p15/15-2
□
Isn't glass shot performed for flux cleaning? (Particle of the glass may
get inside the relay and cause operation failure.)
p13/15-1、p15/15-2
□
Does significant warping of print board occur, which applies a force on a
relay teminal and changes the relay characteristics?
p13/15-1、p15/15-2
□
Isn't the unused terminal cut? (Applied force on terminal can change the
characteristics.)
p13/15-1、p15/15-2
Soldering
□
Any strong forces such as terminal clinch are not applied at attaching. p18/16-3
□
Aren't load, shock, or vibration which is out of the allowable range
applied during transportation?
p18/17-1
□
Are temperature and humidity within the allowable range? p18/17-2
□
Is the ambient atomosphere free from organic gas and sulfidizing gas? p18/17-2
Product
handling
□
Aren't dropped or fallen tube packages used? p18/18-1
Contact
reliability
Storage,
transportation
PCB mounting
Use
environmental
condition
Contact
resistance
Category
Check
box
Check item
Check sheet (2/2)