Panasonic PT-DZ770ULK Projector User Manual


 
Maintenance/replacement
106 - ENGLISH
Maintenance
Lamp unit
The lamp unit is a consumable component. Check the lamp usage time in [PROJECTOR SETUP] → [STATUS]
(
page 72) in the menu and change the lamp periodically.
It is recommended that you request a qualied technician to replace the lamp unit. Consult your dealer.
Consult your dealer to purchase a replacement lamp unit (ET-LAD60A (1 bulb), ET-LAD60AW (2 bulbs)).
Notes on the replacement of the lamp unit
z
Since the luminous lamp is made of glass, it may burst if dropped or hit with a hard object.
Please handle with care.
z
A Phillips screwdriver is necessary when replacing the lamp unit.
z
Make sure you hold the lamp unit by its handles during replacement.
z
The lamp may burst. Replace the lamp unit carefully so that the broken pieces of the lamp glass will not
scatter. If the projector is mounted to the ceiling, do not make the replacement directly beneath the lamp
unit or put your face near it.
z
The lamp contains mercury. When disposing of used lamp units, contact your local authorities or dealer for
correct methods of disposal.
Attention
z
Use only specied lamp units.
Note
z
The model numbers of accessories and optional components are subject to change without notice.
When to replace the lamp unit
The lamp unit is a consumable component. Since its brightness gradually decreases over time, it is necessary
to replace it regularly. The estimated duration before replacement is 2 000 hours. However, this may be
shortened depending on individual lamp characteristics, usage conditions, and the installation environment.
Therefore, it is strongly recommended that a replacement lamp unit be prepared. If the lamp is not replaced
after 2 000 hours of use, a malfunction will occur and the projector will automatically switch off after
approximately ten minutes.
On-screen display Lamp indicator
Over 1 800 hours
The message is displayed for 30 seconds.
Pressing any button on the control panel
or remote control within 30 seconds will
clear the message.
Lights in red even during the standby
mode. (Only the corresponding lamp
lights)
Over 2 000 hours
The message remains displayed until you
press a button.
Note
z
The 2 000 hour usage period is a rough estimate and is not guaranteed.
REPLACE LAMP