Installation
3-133000-A2-GA31-80 December 1994
Figure 3-8. Alarm Output or Ground Strap Terminal Installation
Alarm Output Connection
To connect the alarm output to an external light or
buzzer, install the alarm or buzzer and voltage source as
described in the instructions received with the light/buzzer
and voltage source. Then, use the two ALARM terminals
labeled E1 and E2 at the rear of the carrier to install two
external device leads:
Procedure
1. Use pliers to pull the plastic caps off the E1 and
E2 terminals (Figure 3-8, Step A).
2. Insert the end of the wire coming from the voltage
source and the end of a wire to be connected to the
next carrier into the E1 terminal. It is not
necessary to strip the wires (Figure 3-8, Step B).
3. Fit the wires into the slot in the terminal. Replace
the plastic cap on the terminal, fitting the wires
into the matching slot cut lengthwise in the cap
(Figure 3-8, Step C).
The last carrier to be connected only has one
incoming lead installed and no outgoing lead.
4. Use a Phillips screwdriver to push the cap firmly
onto the terminal. As you seat the cap, the
terminal cuts through the insulation on the wires
and makes contact (Figure 3-8, Step D).
5. Insert the other end of the wire to the next carrier’s
E1 terminal, if any, and repeat Steps 2 through 5
until all the carriers are linked together
(Figure 3-9).
6. Insert the end of the wire coming from the alarm
and the end of a wire to be connected to the next
carrier into the E2 terminal, as described in Step 2.
7. Repeat Steps 3 through 5, connecting the E2
terminals instead, until all the carriers are linked
together (Figure 3-9).