Paradyne Hotwire M/SDSL and HDSL2 Termination Units Network Hardware User Manual


 
Configuration Options
A-22
8700-A2-GB20-00April 2000
Table A-10. Assign Time Slots Options (1 of 1)
(DSX-1/DSL or G.703/DSL Selection)
Possible Settings (Models 8747, 8777): DSX-1, DSL
Default Setting: DSX-1
Possible Settings (Model 8779): G.703, DSL
Default Setting: G.703
Determines the port whose time slots are displayed. The unit can be configured using
the viewpoint of the DSX-1 or G.703 interface, or the DSL network interface.
DSX-1
or G.703 Time slots for the specified DTE port are displayed.
DSL Time slots for the specified DSL port are displayed.
(Port Type )
Possible Settings (Models 8747, 8777): D, X
Default Setting: D
Possible Settings (Model 8779): D, G (see note)
Default Setting: D
Shows the type of port to which this time slot is connected.
D The time slot is connected to a DSL port.
G The time slot is connected to a G.703 port (Model 8779).
X The time slot is connected to a DSX-1 port (Models 8747, 8777).
(Port Number)
Possible Settings: 18
Default Setting: [Blank]
Determines the port to which this time slot is connected.
(Time Slot Number)
Possible Settings (Models 8747, 8777): 124
Default Setting: [Blank]
Possible Settings (Model 8779): 131
Default Setting: [Blank]
Determines the time slot to which this time slot is connected.
(Data/Voice Selection)
Possible Settings: d, v
Default Setting: d
Determines whether the time slot is dedicated to the transmission of voice or data.
d The time slot is used for data.
v The time slot is used for voice.
NOTES:
If a G.703 port is configured for voice, time slot 16 is used for signaling and is
not available for cross-connection.