Security
6-2
8700-A2-GB20-00
April 2000
ATI Access Levels
The Hotwire Termination Unit has two access levels: Administrator and Operator.
The access level determines what functions are accessible, as shown in
Table 6-1.
Table 6-1. Access Levels
ATI Access to Menu Functions
Administrator Operator
Status Read-Only Read-Only
Test Full Access No Access
Configuration Full Access Read-Only
Control Full Access No Access
Access levels can be applied to Login IDs and Telnet sessions. When access is
through Telnet and a login is required for Telnet, the effective access level is the
more restrictive of the Telnet session access level or the login access level. (See
Table A-11, Telnet Session Options.)
When an access level of Operator is applied to Telnet sessions, a Login ID
with Administrator authority is effectively reduced to Operator. It is no longer
possible to change configuration options, and full access can be restored only by
reloading factory defaults. (See Restoring Access to the User Interface in
Chapter 3, Initial Startup and Configuration.)