Standards Compliance for SNMP Traps
B-6
8700-A2-GB20-00April 2000
SNMP Trap Possible CauseDescription
enterpriseFallback
AutoRate(13)
After a loss of signal, the
unit resynchronized to a
lower rate than the last
known rate.
Variable bindings:
H ifIndex (RFC 1573)
H ifAdminStatus
(RFC 1573)
H ifOperStatus (RFC 1573)
H ifType (RFC 1573)
Variable line conditions.
enterprisePrimaryClockFail
Clear(101)
The LTU has recovered and
is using its primary clock
source.
No variable bindings.
enterpriseSecondaryClock
FailClear(104)
The LTU has recovered and
is using its secondary clock
source.
No variable bindings.
enterpriseTestStop(105) All tests have been halted.
Variable bindings:
H ifIndex (RFC 1573)
H ifAdminStatus
(RFC 1573)
H ifOperStatus (RFC 1573)
H ifType (RFC 1573)
H ifTestType (RFC 1573)
All tests on an interface
have been stopped by
timeout or an Abort All Tests
command.
enterpriseFallback
AutoRateClear(113)
After an AutoRate fallback
condition, the unit
resynchronized to the last
known rate.
Variable bindings:
H ifIndex (RFC 1573)
H ifAdminStatus
(RFC 1573)
H ifOperStatus (RFC 1573)
H ifType (RFC 1573)