Paradyne 7975 Network Card User Manual


 
Monitoring the Unit
4-7
7975-A2-GB20-40
December 1998
Use the virtual function keys to page through the intervals and clear statistics.
This Field . . . Contains . . .
Current Interval
Timer
The number of seconds which have elapsed in the current
15-minute interval. Maximum value is 900 seconds (15 minutes).
This counter resets every 15 minutes.
Error Events
Counter
A running total of CRC errors. Range 0 – 65535. This counter
resets when the near-end data is cleared.
Current Interval Performance data for the current 15 minutes.
Interval
xx
Historical performance data for up to 96 15-minute intervals
(24 hours) where the value of
xx
is from 01 to 96.
Worst Interval The number of the interval with the worst (highest) performance
data for both the near- and far-end statistics. If two or more
intervals are equal, the oldest interval is displayed.
Near and Far TOT A running total of the near- and far-end performance statistics.