Paradyne 7975 Network Card User Manual


 
Configuration Option Tables
A-15
7975-A2-GB20-40
December 1998
Table A-7. SNMP Traps Options (2 of 2)
Enterprise Specific Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Determines if SNMP traps are generated for enterprise-specific events.
Enable – SNMP traps are generated for
enterpriseSpecific
events.
NOTE: Refer to
Enterprise Specific Traps
in Appendix B,
Standards Compliance
for SNMP Traps
.
Disable – No enterprise-specific event traps are sent.
Link Traps
Possible Settings: Disable, Up, Down, Both
Default Setting: Both
Determines if SNMP traps are generated for link up and link down for one of the
communication interfaces.
Disable – No
linkUp
or
linkDown
SNMP traps are generated.
Up – A
linkUp
trap is generated when the 7975 Termination Unit recognizes that one of
the communication interfaces is operational.
Down – A
linkDown
trap is generated when the 7975 Termination Unit recognizes a
failure in one of the communication interfaces.
Both – Sends trap messages for detection of both
linkUp
and
linkDown
.
NOTE: Refer to
linkUp and linkDown
in Appendix B,
Standards Compliance for
SNMP Traps
.
Link Trap Interfaces
Possible Settings: Network, SYNC, All
Default Setting: All
Determines if the SNMP
linkUp
, SNMP
linkDown
, and interface-related
enterpriseSpecific
traps are generated for the network interface and synchronous data
(DTE) port, or all.
Network – SNMP trap messages are generated for the network interface.
SYNC – SNMP trap messages are generated for the synchronous data (DTE) port.
All – SNMP trap messages are generated for the network interface and the
synchronous data (DTE) ports.