Parker Hannifin vm24 Webcam User Manual


 
Installing the VM24 15
Input Connections
Caution
Remove power to the VM24 before
making any connections.
Sinking
12
.
1 K
6.81 K
1500 pF
10
.
0 K
+
-
Out 5-24 Volts
Output
Ground
The output should
be able to sink at
least 3mA of current.
Electronic
Device
6000 Series
Controller
ISO
Ground
VM24
External Supply
(up to 24VDC)
+
Ground
Connection
Input
Connection
Ground
Connection
V
i
(J6)
(J5)
(J5)
JUMPER
1
2
3
(J6)
V
i
Input
Connection
Ground
Connection
(J4)
(J4)
30
.
1 K
+5V
IN-P
20
.
0 K
18.2 K
Iso
GND
Iso
GND
Iso
GND
Iso
GND
Sourcing
Out 5-24 Volts
Output
Ground
Electronic
Device
V
1
R
1
12.1 K
6.81 K
1500 pF
10.0 K
Iso
GND
+
-
6000 Series
Controller
Iso
GND
Iso
GND
VM24
External Supply
(up to 24VDC)
+
Ground
Connection
Input
Connection
Ground
Connection
V
i
(J6)
(J5)
(J5)
JUMPER
1
2
3
(J6)
V
i
Input
Connection
Ground
Connection
(J4)
(J4)
30.1 K
+5V
IN-P
20.0 K
18.2 K
Iso
GND
Iso
GND