174 Frame Relay Local Management Interface
933A_Network: The ITU Q.933 protocol will be used. The unit will operate as the Network side of the
connection
933A_User: The ITU Q.933 protocol will be used. The unit will operate as the User side of the connection
933A_Both: The ITU Q.933 protocol will be used. The unit will operate as both the Network and User
side of the connection.
617D_Network: The ANSI T1.617 protocol will be used. The unit will operate as the Network side of the
connection
617D_User: The ANSI T1.617 protocol will be used. The unit will operate as the User side of the connection
617D_Both: The ANSI T1.617 protocol will be used. The unit will operate as both the Network and User
side of the connection.
MgtState
Defines the current state of the DTE side LMI. Possible options are as follows:
Mgt_Port_DOWN: Currently the LMI on the DTE side is DOWN
Mgt_Port_UP: Currently the LMI on the DTE side is UP
mgtAutoStart: (Default Value: FALSE)
The management Auto Start variable allows the user to start the LMI session before any DLCI connections are
created within the unit. If this variable is set to FALSE, the LMI session will begin when the first DLCI channel
is created. If this variable is set to TRUE the LMI session will begin immediately.
T391_Value: (Default Value: 10)
This variable sets the T391 timers in seconds.
T392_Value: (Default Value: 16)
This variable sets the T392 timers in seconds.
fullReportCycle: (Default Value: 6)
This variable represents the N391 protocol value
netErrorWindowSize: (Default Value: 4)
Network side N393 protocol value
netMaxErrors: (Default Value: 3)
Network side N392 protocol value
userErrorWindowSize: (Default Value: 4)
User side N393 protocol value
userMaxErrors: (Default Value: 3)
Network side N392 protocol value