Patton electronic 3086 Network Card User Manual


 
4 • Basic Application Configurations Model 3086 G.SHDSL Integrated Access Device User Guide
46 T1 Interface
Switches S2-1 through S2-7. Use Switches S2-1 through S2-7 to set the data rate (see Table 5 on page 43.
Each position represents nx64 settings.
Switch S2-8. S2-8 activates configuration of Model 3086 via DIP switches. Any time the user desires to mod-
ify the 3086 configuration available through DIP switches, make the changes to the corresponding switches
and then set S2-8, from On to Off position, wait 3-4 seconds and set back to the On position. Changes made
to configuration via DIP switches will not take effect if S2-8 isn’t toggled.
S7 S6 S5 S4 S3 S2 S1 Data Rate (kbps)
On On On On On On Off 64
On On On On On Off On 128
On On On On On Off Off 192
On On On On Off On On 256
On On On On Off On Off 320
On On On On Off Off On 384
On On On On Off Off Off 448
On On On Off On On On 512
On On On Off On On Off 576
On On On Off On Off On 640
On On On Off On Off Off 704
On On On Off Off On On 768
On On On Off Off On Off 832
On On On Off Off Off On 896
On On On Off Off Off Off 960
On On Off On On On On 1024
On On Off On On On Off 1088
On On Off On On Off On 1152
On On Off On On Off Off 1216
On On Off On Off On On 1280
On On Off On Off On Off 1344
On On Off On Off Off On 1408
On On Off On Off Off Off 1472
On On Off Off On On On 1536
S2-8 Condition
ON->Off->ON Implements switch configuration (toggled ON/OFF)