Patton electronic 3086 Network Card User Manual


 
Frame Relay Network Interworking (FRF.5) 185
Model 3086 G.SHDSL Integrated Access Device User Guide F • Interworking Functions Information
not active: No information has been received from the management port related to this channel
CLI Configuration Methods for Port Level Management
The following information can be used to configure the Port Level information associated with the FRN con-
nections. The CLI uses the “frn” directive of the CLI interface for Port Level configuration.
List all ports available to the system
Command: frn list
The “frn list” command will display the current high level state of each port available in the system. More
information about each specific port can be gained by the “show port” command described below. The follow
-
ing shows the output of the “frn list” command.
frn list
----------------------------------------------------------------------
|Port | Name | VPI | VCI | DLCI | Activate | Mux Mode
|port1 | main | 0 | 100 | 100 | disable | mux_one_to_one |
|port2 | backup | 10 | 110 | 110 | disable | mux_one_to_one |
|port3 | none | 20 | 120 | 120 | disable | mux_one_to_one |
|port4 | none | 30 | 130 | 130 | disable | mux_one_to_one |
|port5 | none | 40 | 140 | 140 | disable | mux_one_to_one |
|port6 | none | 50 | 150 | 150 | disable | mux_one_to_one |
|port7 | none | 60 | 160 | 160 | disable | mux_one_to_one |
|port8 | none | 70 | 170 | 170 | disable | mux_one_to_one |
----------------------------------------------------------------------
Show detailed information about a specific port
Command: frn show port#
The “frn show port#” command will display detailed information about the port defined in the command. The
following shows the actual output of the configuration of port 3. Note that the “frn show port” will also dis
-
play information about the channels that are associated with that port.
frn show port1 command output
Port Level Information: Port 1
FRN Port Name: none
FRN VPI: 0
FRN VCI: 100
FRN DE Mapping: zero
FRN CLPI Mapping: fr_sscs_only
FRN Mux Mode: mux_one_to_one
FRN Header Type: 2_byte
FRN DC Mapping: zero
FRN State: enable
FRN Core Name: FRN0
FRN Tx Packets: 146/1