58
7. Open Model 3088RC Console (via HyperTerminal or other terminal
emulation program).
>>Transfer
>>Send Text File...
>>Set “Files of Type:” to “All files (*.*)”
>>Select 033252Z.hex
8. When the transfer completes, turn off the Model 3088RC.
9. Set the DIP switches for the proper configuration.
10.Turn on the Model 3088RC. It now operates with the upgraded soft-
ware.
5.5 RESET CONFIGURATION TO FACTORY DEFAULT
The configuration can be reset to factory defaults from the software reset
mode. This allows a user to recover from a forgotten password. To reset
to the configuration, follow these steps:
1. Power down the unit.
2. Set all DIP switches to the OFF position.
3. Connect a PC to the Console port.
4. Open a VT100 terminal emulator (such as HyperTerminal). Config-
ure the emulator for 19200 bps,1 stop bit, no parity, X-ON X-OFF
flow control.
Note The 3088RC will not wait for its address to be selected when in
software reset mode. It will automatically accept data from the
1001CC.
5. Power up the unit. The terminal should display the following mes-
sage: Reset Mode.
6. Type the ‘*’ key. You will see a ‘:’ prompt.
7. Type the command reset.
8. When the command completes, the unit has been reset to factory
configuration.
9. Set the DIP switches to the desired configuration. Power cycle the
unit to begin using the new configuration.