Patton electronic 2635 Network Router User Manual


 
WAN Service Configuration 59
Models 2603, 2621, and 2635 Getting Started Guide 6 • WAN Services
LMI Configuration Options. The Frame Relay Local Management Interface is configurable through either
the CLI or web interface on the IPLink Series. The following variables are available for configuration.
managementType: (Default Value: no_maintanence) the managementType variable defines the LMI proto-
col that will be used from the table above. The following options are available.
- no_maintenence: No maintenance interface will be used for this frame relay connection.
- ITU Network: The ITU Q.933 protocol will be used. The unit will operate as the Network side of the
connection.
- ITU User: The ITU Q.933 protocol will be used. The unit will operate as the User side of the
connection.
- ITU Both: (NNI) The ITU Q.933 protocol will be used. The unit will operate as both the Network and
User side of the connection.
- ANSI Network: The ANSI T1.617 protocol will be used. The unit will operate as the Network side of the
connection
- ANSI User: The ANSI T1.617 protocol will be used. The unit will operate as the User side of the
connection
- ANSI Both: (NNI) The ANSI T1.617 protocol will be used. The unit will operate as both the Network
and User side of the connection.
Management State: Defines the current state of the DTE side LMI. Possible options are as follows:
- Mgt_Port_DOWN – Currently the LMI on the DTE side is DOWN
- Mgt_Port_UP – Currently the LMI on the DTE side is UP
Management Auto Start: (Default Value: FALSE) The management Auto Start variable allows the user to
start the LMI session before any DLCI connections are created within the unit. If this variable is set to
FALSE, the LMI session will begin when the first DLCI channel is created. If this variable is set to TRUE
the LMI session will begin immediately.
Full Report Cycle: (Default Value: 6) This variable represents the N391 protocol value
User Max Errors: (Default Value: 3) Network side N392 protocol value
Net Max Errors: (Default Value: 3) Network side N392 protocol value
User Error Window Size: (Default Value: 4) User side N393 protocol value
Net Error Window Size: (Default Value: 4) Network side N393 protocol value
T391_Value: (Default Value: 10) This variable sets the T391 timers in seconds.
T392_Value: (Default Value: 16) This variable sets the T392 timers in seconds.
Web Configuration Methods
The following documentation defines how to configure the Frame Relay Local Management Interface using
the Web Interface on the IPLink Series.