If the field does not change, define IFLAG as ‘I’ and set
IVALUE to zero (0).
NOTE: Do not select incrementing on fields that contain a
check digit.
IVALUE One to three digits to define the amount by which the value in
the field increases or decreases as each ticket is printed. If
the field does not change, define IFLAG as ‘I’ and set IVALUE
to zero (0).
Values: 0-999
NOTE: The first number in the count sequence must contain
the same number of digits as the highest number to
be counted. For example, to count the numbers 1 to
999, the first number in the sequence must be entered
as 001.
ROW One to four digits to define the row location of the field on the
supply. This is the distance from the the guide edge zero
point at the bottom of the supply and the bottom of the field.
The zero point is 1.5 mm or 0.060 inches from the bottom of
the supply. The bottom of the supply is the edge that exits the
printer first.
This value is measured in tenths of millimeters (TOMMS) and
must be less than the maximum length of the supply.
Values: 0-2032
COL One to four digits to define the column location of the field on
the supply. This is the distance from the guide edge zero
point at the left edge of the supply and the left edge of the
field.
The zero point is 1.5 mm or 0.060 inches from the left edge of
the supply.
The unit of measurement is tenths of millimeters. The range
must be less than the maximum width of the supply.
Values: 0-1016 (0 to 4 inches)
MAG One to two digits as the magnification factor for the font of
text fields.
Values: 1 - 10
3-10 Message Structures