To install the power cable (refer to Figure 6 on page 13):
1. Run power lines from the power supply to the mount site (refer to the power specifications at the start of this section).
2. Connect the power lines from the power supply to the supplied power cable, as indicated:
NOTES:
Be sure to use environmentally-rated connectors when connecting power to the EW5001. Otherwise, unit reliability may suffer.
The supplied power cable may include other leads that are not used.
If the supplied power cable cannot reach from the power source to the mount site, attach additional power cable. Make sure the cable
is rated for outdoor use.
If you use a junction box or patch panel, make sure the connection is protected from the weather.
Installers should consult local, state, and federal code requirements before installing this cable or running this cable inside any
building. Installers should also use best practices when terminating this or any other cable lead.
3. Run the other end of the supplied power cable to the mount site.
You will connect the power cable to the EW5001 later (refer to Unit Installation on page 19).
Network Cable
The EW5001 requires a network cable that meets the following specifications:
Weatherproof
Silicon filled
Cat5e or greater unshielded twisted pair (UTP)
Long enough to reach the EW5001 from the network switch, up to 328 ft (100 m)
Refer to Optional Accessories on page 5 for a list of approved cables of various lengths that can be purchased from Pelco.
Wire Color DC AC
White DC+ AC+
Black Ground AC-