4.12.6 Cable Diagnostics
The Cable Diagnostics page contains fields for performing tests on copper cables. These functions have the ability to
identify the cable length and operating conditions, and to isolate a variety of common faults that can occur on the Cat5
twisted-pair cabling. There might be two statuses as follow:
If the link is established on the twisted-pair interface in 1000BASE-T mode, the Cable Diagnostics can run without
disruption of the link or of any data transfer.
If the link is established in 100BASE-TX or 10BASE-T, the Cable Diagnostics cause the link to drop while the
diagnostics are running.
After the diagnostics are finished, the link is reestablished. And the following functions are available.
Coupling between cable pairs.
Cable pair termination
Cable Length
Anomalous coupling between cable pairs can be caused by shorted wires, improper termination, or high crosstalk
resulting from an incorrect wire map. These conditions can all prevent the PLANET switch from establishing a link. The
screen in Figure 4-59 appears.
Figure 4-59 Cable Diagnostics
The Cable Diagnostics includes the following fields:
Port
Specifies the port numbers for which to run the cable diagnostics.
Mode
There’re three cable test mode for selection:
Full – test full pairs.
Anomaly – test with only anomaly pairs.
Anomaly w/o X-pair - test anomaly pairs but without X-pair.
The Cable status includes the following items: