Planet Technology SGSW-2840P Switch User Manual


 
User’s Manual of SGSD-1022 / SGSD-1022P
SGSW-2840 / SGSW-2840P
416
Command Mode
Privileged Exec
Example
This example shows the default engine ID.
Console#show snmp engine-id Local SNMP engineID:
8000002a8000000000e8666672 Local SNMP engineBoots: 1
Remote SNMP engineID
80000000030004e2b316c54321
Console#
IP address
192.168.1.19
Field Description
Local SNMP
engineID
String identifying the engine ID.
Local SNMP
engineBoots
The number of times that the engine has (re-)initialized
since the snmp EngineID was last configured.
Remote SNMP
engineID
String identifying an engine ID on a remote device.
IP address IP address of the device containing the corresponding
remote SNMP engine.
snmp-server view
This command adds an SNMP view which controls user access to the MIB. Use the no form to remove an SNMP view.
Syntax
snmp-server view view-name oid-tree {included | excluded} no snmp-server view view-name
•view-name -Name of an SNMP view. (Range: 1-64 characters)
•oid-tree - Object identifier of a branch within the MIB tree. Wild cards can be used to mask a specific portion of the OID
string. (Refer to the examples.)
included - Defines an included view.
excluded - Defines an excluded view.
Default Setting
defaultview (includes access to the entire MIB tree)
Command Mode
Global Configuration
Command Usage
Views are used in the snmp-server group command to restrict user access to specified portions of the MIB tree.