Downloading The EVFU (Using The PI Line)
73
The Skip to Channel Command
The skip to channel command has the following format:
Bit NumberFunction
PI76543210
1XXX0CCCCSkip to channel CCCC
(X bits not used)
CCCC:0000 = Channel 10110 = Channel 7
0001 = Channel 20111 = Channel 8
0010 = Channel 31000 = Channel 9
0011 = Channel 41001 = Channel 10
0100 = Channel 51010 = Channel 11
0101 = Channel 61011 = Channel 12
Slew “N” Lines
Bit NumberFunction
PI76543210
1XEE1NNNNAdvance paper the number
of lines specified by NNNN
or EENNNN,
Up to 63 lines (all bits EENNNN are 1) can be slewed. If the number of lines is
63, and the option “Truncate PI slew” is set to “Truncate at TOF,” the slew will
be aborted at Top of Form, if the distance from the current position to the next
Top of Form is less than 63 lines.