Q-Logic 59021-05 B Switch User Manual


 
B – Command Line Interface
Set Config Command
B-30 59021-05 B
Q
zoning
Initiates an editing session in which to change switch zoning attributes. The
system displays each parameter one line at a time and prompts you for a value.
For each parameter, enter a new value or press the Enter key to accept the
current value shown in brackets.
Examples The following is an example of the Set Config Port command:
SANbox2 #> admin start
SANbox2 (admin) #> config edit
SANbox2 (admin-config) #> set config port 1
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Configuring Port Number: 1
------------------------
AdminState (1=Online, 2=Offline, 3=Diagnostics, 4=Down) [Online]
LinkSpeed (1=1Gb/s, 2=2Gb/s, 3=Auto) [Auto ]
PortType (TL / GL / G / F / FL / Donor) [GL ]
ISLSecurity (Any / Ours / None) [Any ]
SymPortName (string, max=32 chars) [Port1 ]
ALFairness (True / False) [False ]
DeviceScanEnable (True / False) [True ]
ForceOfflineRSCN (True / False) [False ]
ARB_FF (True / False) [False ]
InteropCredit (decimal value, 0-255) [0 ]
ExtCredit (dec value, increments of 11, non-loop only) [0 ]
Table B-10. Set Config Zoning Parameters
Parameter Description
AutoSave Enables (True) or disables (False) the
saving of changes to active zone set in
the switch’s permanent memory.
Changes are always saved in the
switch’s temporary memory.
Default Enables (All) or disables (None)
communication among the switch’s
ports/devices and the fabric in the
absence of an active zone set.