Q-Logic 8200 Network Cables User Manual


 
1–Product Overview
Adapter Specifications
1-4 SN0054671-00 A
Environmental Specifications
Table 1-1. Environmental Specifications
Condition Operating Non-Operating
Temperature Ranges
(for Altitude=900 m or 2952.75 ft)
10°C to 55°C
a
(50°F to 131°F)
a
200LFM is required to operate at this temperature.
–40°C to 65°C
(–40°C to 149°F)
Temperature Ranges
(for Altitude >900 m or 2952.75 ft)
10°C to n°C
b
(50°F to n°F
c
)
b
Use the following formulas to calculate the maximum operating temperature (in °C) for a specific
altitude. Use the first formula if the altitude is stated in meters and the second formula if the altitude
is stated in feet.
c
Use the following formulas to calculate the maximum operating temperature (in °F) for a specific
altitude. Use the first formula if the altitude is stated in meters and the second formula if the altitude
is stated in feet.
–40°C to 65°C
(–40°F to 149°F)
Temperature Gradient Maximum
per 60 Min.
10°C 20°C
Humidity Percent Ranges—Non-
condensing
20% to 80%
(Max Wet bulb temper-
ature= 29°C)
d
d
Maximum corrosive contaminant levels measured at =50% relative humidity; see Table 3 in
ISA-71.04-1985.
5% to 95%
(Max Wet bulb tempera-
ture= 38°C)
d
Humidity Gradient Maximum
per 60 Min.
10% 10%
Altitude Ranges—Low Limits –15.2m (–50 ft) –15.2m (–50 ft)
Altitude Ranges—High Limits 3,048m (10,000 ft) 10,668m (35,000 ft)
Airborne Contaminants—ISA-71
Level
G1
d
G1
d