18
Notes: 1. When the HDI is not linked up even if the above procedure has been executed, the
driver will not be set correctly. Install drivers provided with the \SETUP
directory in the CD-R according to the screen instructions.
2. If the user system interface cable is disconnected to the Hitachi-UDI port
connector on the user system during user program execution, the following dialog
box will be displayed.
Figure 2.11 [H-UDI Connector Disconnected] Dialog Box
3. If the emulator is not initiated, the following dialog boxes shown in figures 2.12
through 2.15 will be displayed.
(a) If the following dialog box is displayed, the user system may not be turned on or
the RESET signal may not have been correctly input to the MCU. Check the
power supply and input circuit for the reset pin on the user system.
Figure 2.12 [Can not find /RESET signal] Dialog Box