ACTIVE RECORDING AND VIDEO LOSS SETTING Menu 5
ACTIVE REC Settings Examples
Example 1:
Recording on the tape when an alarm trigger is received from camera 2
Example 2: Recording on the tape when an alarm trigger is received from camera 4 when an
alarm trigger has already been received from camera 2
NOTE: The ACTIVE REC examples are given for function illustration purposes only. The actual recordings will vary according to the
various settings.
Camera 2 picture
02
02
02
01
01
02
02
04
04
05
05
06
06
07
07
08
08
09
09
10
10
11
11
12
12
13
13
14
14
15
15
16
16
01
01
(Normal)
(REC MODE: MODE1)
(REC MODE: MODE2)
Alarm trigger in Alarm trigger out
Alarm trigger in Alarm trigger out
Normal recording
(no alarm trigger)
Alarm duration for camera 2
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 01
01
01
02
02
02
02
01 02 03 04 02 02
02
02 02
02
02 02
02
02 02
02
02 02
02
02 02
02
02 02
02
02 05 06 07 08
01 02 03 04 05 06 07 08 09 10 11 12
02
02
02 02
02
02 02
02
02 02
02
02
Alarm duration for camera 2
Camera 2 picture Camera 4 picture
02
02
02
04
04
04
01
01
02
02
04
04
05
05
06
06
07
07
08
08
09
09
10
10
11
11
12
12
13
13
14
14
15
15
16
16
01
01
01 03 04
01 02 03 04
01 02 03 04
05 06 07 08 09 10 11 12 13 14 15 16 01
02
02
05
05
02
02
04
04
06
06
02
02
07
07
04
04
08
08
04
04
09
09
04
04
10
10
11
11
02 05 02 04 06 02 07 04 08 04 09 04 10 11
(Normal)
(REC MODE: MODE1)
(REC MODE: MODE2)
Alarm trigger in Alarm trigger in
Alarm trigger in Alarm trigger in
Alarm trigger out Alarm trigger out
Alarm trigger out Alarm trigger out
02
02
02
02
02
02
04
04
02
02
04
04
02
02
04
04
04
04
04
04
04
04
04
04
05
05
06
06
02 02 02 04 02 04 02 04 04 04 04 04 05 06
02
Alarm duration for
camera 2
Alarm trigger received from camera
4 during the alarm duration for
trigger from camera 2
Alarm duration for camera 2 is over,
remaining alarm duration for trigger
from camera 4
Alarm duration for
camera 2
Alarm trigger received from camera
4 during the alarm duration for
tri
gg
er from camera 2
Alarm duration for camera 2 is over,
remaining alarm duration for trigger
from camera 4
L8FC5/US (MPX-CD162, MD162 GB) 2000. 8. 31