Electrical Specifications - Power, continued
Bias Input
Specifications
Table
The following table provides 17S bias input specifications.
Note: The bias input also provides power to the optional motor brake.
External Fuse
Specifications
Table
The following table provides 17S external fuse specifications.
Continued on next page
Motor Brake Present Bias Input Value
No Voltage 20 ... 30 Vdc
Current 0.75 A to 1.2 A
Yes Voltage 24 Vdc -10%, +5%
Current 3 A max.
Input Type Model Number Fuse
Line MHDS1004N00 6 A, time delay
MHDS1008N00
MHDS1017N00 10 A, time delay
MHDS1028N00
MHDS1056N00 20 A, time delay
Optional external
Regen
MHDS1004N00 4 A, fast acting*
MHDS1008N00
MHDS1017N00 6 A, fast acting*
MHDS1028N00
MHDS1056N00
*Two fuses in series, >= 500 V, dimensions: 10 x 38.