Electrical Specifications - Regen Resistor
Regen Circuit
Specifications
The following table provides technical data on the Regen circuit.
Parameter Rated data Units Model Number
(prefix with MHDS10)
04N00
08N00
17N00
28N00
56N00
Supply Voltage 3
phase
,
230 V
Upper switch-on level of Regen circuit V 400 - 430
Switch-off level of Regen circuit V 380 - 410
Continuous power of Regen circuit (RBint) W 80 200
Continuous power of Regen circuit (RBext)
maximum.
kW 0.25 0.75
Pulse power, internal (RBint max. 1s) kW 2.5 5
Pulse power, external (RBext max. 1s) kW 5
3 phase
,
400 V
Upper switch-on level of Regen circuit V 720 - 750
Switch-off level of Regen circuit V 680 - 710
Continuous power of Regen circuit (RBint) W 80 200
Continuous power of Regen circuit (RBext)
max.
kW 0.4 1.2
Pulse power, internal (RBint max. 1s) kW 8 16
Pulse power, external (RBext max. 1s) kW 16
3 phase
,
480 V
Upper switch-on level of Regen circuit V 840 - 870
Switch-off level of Regen circuit V 800 - 830
Continuous power of Regen circuit (RBint) W 80 200
Continuous power of Regen circuit (RBext)
maximum.
kW 0.5 1.5
Pulse power, internal (RBint maximum 1s) kW 10.5 21
Pulse power, external (RBext maximum 1s) kW 21
External Regen resistor
33