Schneider Electric 17S Series Network Router User Manual


 
85
Environmental and Mechanical Specifications
Environmental
Specifications
Table
The following table provides 17S environmental specifications.
Continued on next page
ENVIRONMENTAL
Storage High temperature,
non–operating
+70
°C maximum
Low temperature,
non–operating
–25
°C minimum
Humidity Non–operating 95% RH maximum,
non-condensing
Operating 85% RH maximum,
non-condensing
Operating temperature
(ambient measured at fan inlet)
Full power
With linear derating
2,5% / °C
(available power: 75% of
rated output at 55
°
C)
0 ... 45°C
45 ... 55°C max
Vibration (operational) 10 ... 57 Hz Sinusoidal, 0.75 mm
amplitude
57 ... 150 Hz 1.0 g
Air pressure Operating:
Full power
With linear derating
1,5% / 100m
(available power: 75%
of rated output at
2500m)
1000 m (90 kPa)
1000 ... 2500m (73kPa) max
Transport 57 kPa (4540 m)
Contaminants Pollution degree 2, as defined in EN60204/EN50178
Cooling Models:
MHDS1004N00
MHDS1008N00
MHDS1017N00
MHDS1028N00
MHDS1056N00
Integrated heatsink with
internal fan.