85
Environmental and Mechanical Specifications
Environmental
Specifications
Table
The following table provides 17S environmental specifications.
Continued on next page
ENVIRONMENTAL
Storage High temperature,
non–operating
+70
°C maximum
Low temperature,
non–operating
–25
°C minimum
Humidity Non–operating 95% RH maximum,
non-condensing
Operating 85% RH maximum,
non-condensing
Operating temperature
(ambient measured at fan inlet)
Full power
With linear derating
2,5% / °C
(available power: 75% of
rated output at 55
°
C)
0 ... 45°C
45 ... 55°C max
Vibration (operational) 10 ... 57 Hz Sinusoidal, 0.75 mm
amplitude
57 ... 150 Hz 1.0 g
Air pressure Operating:
Full power
With linear derating
1,5% / 100m
(available power: 75%
of rated output at
2500m)
1000 m (90 kPa)
1000 ... 2500m (73kPa) max
Transport 57 kPa (4540 m)
Contaminants Pollution degree 2, as defined in EN60204/EN50178
Cooling Models:
MHDS1004N00
MHDS1008N00
MHDS1017N00
MHDS1028N00
MHDS1056N00
Integrated heatsink with
internal fan.