Schneider Electric Communication Drivers Computer Drive User Manual


 
Functions
144
X-Way Test tab This tab is used to test the basic operation of an X-Way driver:
The table below describes the different zones of the window:
Driver Group
Field Description
Name Name of driver to be used for the test (Uni-Telway, FPC10, etc).
Driver number Instance number of driver to be used for the test (usually 1).
Remote Address X-Way remote station address in the format "network.station.gate". The
address "0.254.0" is the default address (terminal port for example).
For a network connection, (such as Fipway), the user must complete
this field: "3.5.0" to address station 5 of network 3. Gate 0 corresponds
to the system server gate of the station in question.
Local Address Internal address used locally by the driver. The driver completes this
field automatically for information purposes when the connection
becomes effective.
Request Group
Field Description
Request Name of driver to be used for the test (Uni-Telway, FPC10).
Type Type of request. Different sizes of mirror requests are suggested, as
well as reading the PLC %S6 system bit.
Delay Wait timeout in ms for the response to the transmitted request (time
out).
Status Status of connection, " disconnected ", " connecting... " or
" connected ".
Management properties of SCHNEIDER drivers
MODBUS SERIAL Driver
PCX57 Driver
UNITELWAY Driver
FPC10 Driver FPP20 Driver MODBUS Test XWayTest
OK
MIRROR (3 bytes)
Request
Request:
XIP Driver
DRIVERS Manager
Uni-Telway
Driver
Name:
3000
Status: disconnected
Type:
Delay (ms)
1
Driver number:
0.254.0
Remote address:
Local Address:
Connect Launch Further information... Concerning