Schneider Electric Communication Drivers Computer Drive User Manual


 
Installation
83
Example The architecture below describes the addressing of stations on Ethernet and Fipway
networks:
Access to
stations
To directly access all the stations on the Ethernet 1 network from station A, enter the
X-Way address {1.*} and the IP address 84.0.1.1.
In order for station A to be able to access station B, enter for connection the X-Way
address {1.2} and the IP address 84.0.1.2.
In order for station A to be able to access station B, enter the X-Way address {2.3}
and the IP address of the bridge 84.0.1.2.
How to add a
connection
From the configuration screen,
Ethernet (1)
Fipway (2)
Adresse X-Way {1.1}
Adresse IP 84.0.1.1
Station A
Adresse X-Way {1.2}
Adresse IP 84.0.1.2
Adresse X-Way {2.2}
Adresse IP 84.0.1.2
Adresse X-Way {2.3}
Adresse IP 84.0.1.2
Station C
Station D
Station B
Step Action
1 In the New connection window, enter:
the name of the remote station or bridge,
the address of the remote station or bridge,
the IP address of the remote station or bridge,
2 Click Add.
3 Click Save.